Repeating Detail Components
Jump to navigation
Jump to search
Basics |
Datum Elements |
Model Elements |
Live Annotation |
Drafting Annotation |
Views |
Advanced Concepts |
Settings |
v • t • e |
System Family: Repeating Detail
Purge Unused: Families > Detail Items > Repeating Detail
OOTB
Type | Pattern | ||||
---|---|---|---|---|---|
Detail | Layout[1] | Inside | Spacing | Detail Rotation[2] | |
CMU | CMU Standard : 8" x 8" | Fixed Distance | [ ] | 0' 8" | None |
Metal Deck | Metal Deck : 1 1/2" | Fixed Distance | [ ] | 0' 6" | 90° Clockwise |
Structural Analysis-Default KAI.rte (R2015 .3352. 2017-05-05)
first Load Detail Components (A307 Bolts-Nut.rfa, Reinf Bar Section.rfa [OOTB], WWF.rfa)
Type | Pattern | ||||
---|---|---|---|---|---|
Detail | Layout[1] | Inside | Spacing | Detail Rotation[2] | |
#6 AT 12" (exact) | Reinf Bar Section : #_6 | Fixed Distance | [ ] | 1' 0" | None |
#6 AT 12" MAX[3] | Reinf Bar Section : #_6 | Maximum Spacing | [ ] | 1' 0" | None |
(_) #6[3] | Reinf Bar Section : #_6 | Fixed Number | [ ] | 1' 0" | None |
CMU | CMU Standard : 8" x 8" | Fixed Distance | [ ] | 0' 8" | None |
Metal Deck | Metal Deck : 1 1/2" | Fixed Distance | [ ] | 0' 6" | 90° Clockwise |
NUT - 3/4"ø BOLT AT 3" | A307 Bolts-Nut : 3/4" | Fixed Distance | [ ] | 0' 3" | None |
WWF | WWF | Fixed Distance | [ ] | 0' 6" | 90° Clockwise |
TODO: fix "Metal Deck" family types to align w/ standard profile names & dimensions; delete "CMU" type or make one more useful?
2017-07-18: 2016 template already had A307 Bolts-Nut.rfa loaded (didn't reload)
Ideas
- be able to "explode" a Repeating Detail
- IDEA:Expose Repeated Detail Component to API by ttonsing - they appear to be Detail Lines, but attempts have failed: Place repeating detail using the API, Place Repeating Detail Again, and AUGI's Repeating Details Do able via the api?
Notes
- ↑ 1.0 1.1 Layout: "Fill Available Space" [uses DC's size as the distance], "Fixed Distance", "Fixed Number" ["Number" is an instance parameter (and defaults to 3)], or "Maximum Spacing"
- ↑ 2.0 2.1 Detail Rotation: "None", "90° Clockwise", "90° Counterclockwise", or "180°"
- ↑ 3.0 3.1 2020-08-31 LJC: renamed "#6 AT 12" (distributed)" to "#6 AT 12" MAX" for clarity, added "(_) #6"